Home | About Us | Current Issue | Ahead of print | Archives | Search | Instructions | Subscription | Feedback | Editorial Board | e-Alerts | Login 
Journal of Indian Association of Pediatric Surgeons
     Journal of Indian Association of Pediatric Surgeons
Official journal of the Indian Association of Pediatric Surgeons         
 Users Online:207 
  Print this page Email this page   Small font sizeDefault font sizeIncrease font size
 ORIGINAL ARTICLE
Year : 2007  |  Volume : 12  |  Issue : 2  |  Page : 65-67

Evaluation of the vascularity of an isolated bowel segment using fluorescein angiography in rats


1 Department of Pediatric Surgery, All India Institute of Medical Sciences, New Delhi, India
2 Department of Ophthalmology, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
V Bhatnagar
Department of Pediatric Surgery, All India Institute of Medical Sciences, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9261.33209

Rights and Permissions

Aims: An isolated bowel segment (IBS), a viable loop of bowel completely free of its mesenteric attachments, has potential clinical use in bowel lengthening and other techniques. The end point of successful creation of an IBS is the development of adequate collateral circulation. In this experimental study, we report the use of fluorescein test to demonstrate collateral vascularity of the IBS in rats. A simple technique for the visualization and photography of fluorescein in the tissues is also described. Materials and Methods: In nine Wistar rats, 5 cm of distal ileum was anastomosed side-to-side to 5 cm of proximal colon using 6/0 PDS. In one rat (control), the colon patch was isolated from the rest of the large bowel immediately and fluorescein test was performed. The remaining eight (study group) rats were operated after 8 weeks and the procedure followed as in the control rat. In the last rat, the mesentery of the colon patch was severed; and 2 weeks later, the fluorescein test was performed. Results: The colon patch in the control rat showed complete lack of fluorescence; in the seven rats tested after 8 weeks, patchy fluorescence was demonstrated in the colon patch; and in the last rat, bright fluorescence of the whole patch could be demonstrated within a few seconds following fluorescein injection. Conclusion: This study describes a simple technique for the fluorescein test. The observation that the vascular collaterals were more abundant after mesocolic division was obviously due to the opening up of collaterals over a period of time. The fluorescein test is a rapid and easy test and can be easily reproduced.






[FULL TEXT] [PDF]*


        
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4964    
    Printed179    
    Emailed0    
    PDF Downloaded187    
    Comments [Add]    

Recommend this journal

 


Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer | Privacy Notice

 © 2005 - Journal of Indian Association of Pediatric Surgeons | Published by Wolters Kluwer - Medknow 

Online since 1st May '05