Home | About Us | Current Issue | Ahead of print | Archives | Search | Instructions | Subscription | Feedback | Editorial Board | e-Alerts | Login 
Journal of Indian Association of Pediatric Surgeons
     Journal of Indian Association of Pediatric Surgeons
Official journal of the Indian Association of Pediatric Surgeons         
 Users Online:218 
  Print this page Email this page   Small font sizeDefault font sizeIncrease font size
 ORIGINAL ARTICLE
Year : 2022  |  Volume : 27  |  Issue : 1  |  Page : 32-37

Fogarty catheter: An indispensable tool to complement the ingenuity of the endoscopist for extraction of airway “foreign body with a hole”


Department of Pediatric Surgery, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Dr. Prabudh Goel
Room No. 4002, 4th Floor, Teaching Block, All India Institute of Medical Sciences, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jiaps.JIAPS_245_20

Rights and Permissions

Introduction: The extraction of smooth spherical objects is challenging as they are difficult to grasp within the jaws of the forceps and tend to slip distally. Objective: The authors herein have shared their experience with the use of a Fogarty catheter (FC) for safe extraction of smooth and spherical “foreign body (FB) with a hole.” Materials and Methods: Report on pediatric cases (n = 4) of airway “FB with a hole” wherein the FC was used for their extraction. Mean age was 27.5 months (range: 17 months–39 months). The male: female ratio was 3:1. The technique of FB extraction with a FC has been described, including the principle of the technique, indications, and contra-indications, technical problems and troubleshooting. Results: The FB spectrum included a necklace bead (n = 2), nonnecklace bead (n = 1) and a fragmented end-piece of the housing of a ball-pen (n = 1). The locations of the FBs were right main bronchus (n = 1), secondary bronchus on the right (n = 1), and in the left main bronchus (n = 2). Successful removal of FB with use of FC during rigid broncoscopy was possible. The bead had to be rotated in n = 2 patients to align the hole with the FC. Problems associated with threading the hole and disimpaction of the FB have been highlighted. No complications were observed. The advantages and limitation of the technique have been discussed. Conclusions: The use of FC with the described technique offers a safe, effective and reproducible method for removal of airway “FB with a hole” in a controlled environment while minimizing the possibility of iatrogenic injury to the wall of the surrounding airways.






[FULL TEXT] [PDF]*


        
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed171    
    Printed0    
    Emailed0    
    PDF Downloaded11    
    Comments [Add]    

Recommend this journal

 


Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer 

  2005 - Journal of Indian Association of Pediatric Surgeons | Published by Wolters Kluwer - Medknow 

Online since 1st May '05